Australia Free Web Directory

Adam’s Air & Refrigeration | Local service



Click/Tap
to load big map

Adam’s Air & Refrigeration

Phone: +61 488 106 909



Reviews

Add review



Tags

Click/Tap
to load big map

23.01.2022 Old Fujitsu multi head unit replaced with 5 and 3.5kw Mitsubishi Electric’s



22.01.2022 New system fitted to an existing coolroom after the old evaporator was found with multiple pin hole refrigerant leaks and could not be repaired.

22.01.2022 On farm coolroom has not worked since being transported to site. Repaired damaged pipe work, replaced the liquid line filter drier, condenser fan motor, compressor start and run capacitors, pressure tested with nitrogen, evacuated, charged with refrigerant and tested operation. Up and running again

22.01.2022 Won’t be a hot summer where these two are going!



21.01.2022 Have been a bit slack on the posts lately, just finished off this 33kw Actron Split ducted. Will make a good spot to hide from the

19.01.2022 Reverse cycle split ducted air conditioner not operating due to a hot joint on the compressor contactor. Swapped it out, good to go

19.01.2022 Replaced leaking evaporator and fitted new Carel digital thermostat, liquid line pump down solenoid valve, dual pressure safety, liquid line drier and site glass. Back in business



17.01.2022 7.1 KW Mitsubishi Electric split system supplied and installed to replace existing unit.

16.01.2022 3.5kw Daikin split system air conditioner, supplied and installed ready for summer

15.01.2022 3.5kw wall mounted split system getting a new indoor fan motor, pc board and coil clean! Lives again

14.01.2022 Wont be a hot summer where these two are going!

14.01.2022 Evaporative cooler decommissioned and removed and an 8.5 and 3.5 kw split system put back in.



11.01.2022 Service call for a reverse cycle split ducted air conditioner outside of Walgett with no screen on the wall control. Found remote start/stop relay faulty, replaced with spare from vehicle stock and had it up and running first visit!

10.01.2022 Beating the heat

10.01.2022 Another bedroom that will be cool this summer

09.01.2022 Coolroom not cooling in Collarenebri. Found refrigerant leak on the TX Valve, repaired the connection with new flare and nut, evacuated and charged with refrigerant. Refrigerant R404A and flare nuts stocked at all times.

06.01.2022 New single door glass upright display fridge supplied for the Walgett Show Society thanks to Moree Real Estate

05.01.2022 Glass door upright fridge noisy and not getting to temperature. Replaced condenser fan motor and cleaned condenser, back up and running in one visit

03.01.2022 Upgraded this very old belt driven R22 shop coolroom unit with new evaporator, TX valve, pipe work, controls etc. Hooked it all up to an existing condensing unit completely re wired from switch board to compressor and fitted with all new safetys, discharge pressure control, liquid line drier, site glass etc. Now running on R134A better than ever

02.01.2022 Summer is definitely here! Stay cool!

01.01.2022 Old Fujitsu multi head unit replaced with 5 and 3.5kw Mitsubishi Electrics

Related searches