25.01.2022 Which solar is best? http://inverterrepairsadelaide.com.au//which-solar-invert/



23.01.2022 Its become obvious with our work that customers with solar systems still dont clearly understand what the "Net Feed In Tariff" (NFIT) means. So in this blog, Im going to explain it basic terms. Unfortunately, most sales people when selling to customers never bothered to explain what the NFIT means or how it works. This left consumers confused so in basic terms... [ 1001 more words. ] http://inverterrepairsadelaide.com.au//net-feed-tariff-ex/

22.01.2022 Check Your Inverter After Storms! http://inverterrepairsadelaide.com.au//check-your-solar-i/

22.01.2022 http://inverterrepairsadelaide.com.au//bill-shock-looms-a/



21.01.2022 Power-One (Aurora) inverters have been widely used in solar systems around Adelaide. However they suffer from a regular issue which is an E031 error. Learn more about what to do on our blog. http://inverterrepairsadelaide.com.au//abbaurora-power-on/

20.01.2022 http://inverterrepairsadelaide.com.au//macsolar-replaced-/

19.01.2022 ***BE SURE TO CHECK WITH SMA BEFORE UPGRADING STRING FUSES*** Blown fuses are not covered by SMA warranty. In some cases, string fuses may be upgraded if the input has been combined to one (as was in this case). It seems in this case that the single input to the inverter is sitting at the threshold of the 16A rating of the string fuse. Throw in some heat and full production around summer time and its enough to blow the fuse.... According to SMA in this particular case and having checked the panels specs, I was advised that I could upgrade the string fuse to 20A which should solve the issue. Its either this, or locate the installer to revisit the job (after 3 years!) and rewire the strings so theres more than one input into the inverter. Dont like our chances! This video has been made simply to make others aware that if youre considering installing a large number of panels and using only 1 string input on an SMC10000TL-10 inverter, this issue may occur and cost you time and money. Blown fuses are not covered by SMA warranty.



19.01.2022 Were pleased to announce that we have built a new website for Inverter Repairs & Replacement Services Adelaide. The new site will allow us to update the industry with latest news and allow for customers to interact with us via comments on posts. If youre interested in battery storage for your solar system, you can register for our mailing list on the home page here: www.inverterrepairsadelaide.com.au http://inverterrepairsadelaide.com.au/2016//14/new-website/

18.01.2022 We spent some time testing this new technology L.E.D. light in our own back yard and we have to report, its an absolute ripper! Be warned, they arent for backyard gardens because of the price but if you work for, or know someone who works for a council, you need to check these L.E.D. solar lights out. Theyre made from solid marine aluminium and are available in many combinations to suit your landscape. [ 121 more words. ] http://inverterrepairsadelaide.com.au//commercial-grade-s/

18.01.2022 If you have a failed Aero-Sharp inverter you need to read this blog here... http://inverterrepairsadelaide.com.au//fronius-galvo-repl/

17.01.2022 The never ending story of yet another Eversolar inverter failing only to be replaced by a top grade brand - Fronius Galvo. This broken Eversolar was a 2Kw unit bit it had a max input wattage of 2.275Kw being delivered to it from the panels. The open circuit DC voltage (Voc) exceeded the input voltage range for a Galvo 2.0-1 (2Kw) inverter. [ 165 more words. ] http://inverterrepairsadelaide.com.au//another-eversolar-/

17.01.2022 This is exciting news for residents living in the Adelaide City Council area if you have solar panels on your roof. Residents residing in the ACC area who have an existing solar PV system can now claim up to $5,000 in rebate to help cover the cost of installing battery storage. This is a great incentive to add to your renewable energy system but you need to be aware that you MAY lose your current feed in tariff. [ 67 more words. ] http://inverterrepairsadelaide.com.au//adelaide-city-coun/



16.01.2022 If you have a Fronius or for that matter any brand inverter which has nothing on the display, the problem can be one of two things. Every grid connected solar inverter relies on the DC power coming down from the solar panels to power up the inverter. If you see nothing on the display and no lights at all, it may well not be your inverter thats the problem. [ 319 more words. ] http://inverterrepairsadelaide.com.au//fronius-completely/

16.01.2022 Commercial Quality Solar Light http://inverterrepairsadelaide.com.au//commercial-quality/

16.01.2022 http://inverterrepairsadelaide.com.au//hidden-cost-of-sol/

15.01.2022 http://inverterrepairsadelaide.com.au//abb-power-one-inve/

15.01.2022 SMA inverters which are wired to the AC output directly on the printed circuit board and bypass the supplied plug system (on the bottom of the inverter) will void the warranty instantly. SMA have confirmed by email to us that bypassing the wiring in any inverter in their range which has a built in AC plug system voids the warranty from the day of installation. Weve come across this issue quite a lot where the connectors used to connect to the AC terminals are poorly installe...d and create a loose connection and eventually (under load) break down and begin to arc to a point where the connection fails. Worse still, arcing has occurred and causing flashing and severe burning which then becomes a fire hazard. Due to the failed connection, the inverter shows an error because it cant connect to the grid and the customer is without an operating solar system. The responsibility and liability falls directly on the installer and therefore they are required to replace the inverter at their cost. All installers need to be aware of this issue and ensure that all AC connections are done using the provided plug system built into the inverter.

15.01.2022 Sharp JH-1600E inverters showing a D-21 or D-27 error are common place, especially after storms. This post explains how to easily get your system up and running again using Fronius Galvo as a perfect replacement. http://inverterrepairsadelaide.com.au//sharp-jh-1600e-d-2/

14.01.2022 This inverter stopped working after a spike went through the grid and the internal circuit connecting to the grid blew a component and the error showing on the display was "No Utility". Clenergy inverters cannot be repaired on site so an exchange was fitted under warranty.

12.01.2022 You can also download all this information in .PDF format here (2 pages). This information is provided so you can better understand how your solar system works, how the Net Feed-In Tariff works and how you can better utilise the performance of your solar system to save money on your electricity bills. If youre in the fortunate situation where youre receiving $0.44 cents (or more) per Kilowatt Hour (KwHr) feed-in tariff legislated by state Governments, over and above this Government solar rebate you (may) also receive a top up rebate from the electricity retailer currently supplying the power to your property. [ 1827 more words. ] http://inverterrepairsadelaide.com.au//tips-tricks-get-th/

11.01.2022 As an electrician, Im always asked the golden question... "is it cheaper to wash your dishes in a sink of water or in a dishwasher?" Im really tired of lying sales people who know nothing about electrical consumption telling people dishwashers are less expensive to use. In this blog, Im going to lay it all out clearly so if you read what I write, youll completely understand that running a dishwasher [ 732 more words. ] http://inverterrepairsadelaide.com.au//the-cost-of-dishwa/

11.01.2022 BEWARE! Of energy comparison websites. If youve ever wanted to change electricity retailers but found it all too hard, think again. This new blog will explain everything in easy to understand terms and make it a breeze to search for an alternative. http://inverterrepairsadelaide.com.au//beware-energy-comp/

10.01.2022 If your solar inverter fails, there are two major benefits in exchanging it to a Fronius Galvo. The first is if you order your new inverter before June 30, 2016, it will come with a 5+5 Year warranty. This means youll receive a 5 year full manufacturers warranty PLUS a 5 year PARTS ONLY warranty at no extra charge. The second benefit is that if something does go wrong with your new inverter, we repair the unit on site. [ 87 more words. ] http://inverterrepairsadelaide.com.au//fronius-galvo-offe/

08.01.2022 Wherever possible we replace broken inverters with Fronius because of their new technology and the fact that we repair them ON SITE if something does go wrong. We had a call from a customer whos inverters were damaged due to a lightening strike on their property (or nearby) and we replaced them just this morning with 2 Galvos. Before anyone comments, we added the "Shutdown Procedure" labels after the photo was taken. [ 119 more words. ] http://inverterrepairsadelaide.com.au//kaco-replaced-fron/

08.01.2022 http://inverterrepairsadelaide.com.au//solax-replaces-gro/

07.01.2022 Fronius IG Series up to and including IG30 (3Kw) inverters have two printed circuit boards inside them. One is a DC-AC board and the other is a DC-DC board. The TEST-COM error indicates that the DC-DC board is faulty. This board can be replaced on site but if your inverter is out of warranty it can be a costly exercise. If your inverter has this error, [ 42 more words. ] http://inverterrepairsadelaide.com.au//fronius-test-com-e/

05.01.2022 This is becoming almost a daily routine for us now. Yet another Eversolar inverter has been replaced today with a SolaX. The Eversolar had the usual problem not being able to connect to the grid due to internal failure. DC and AC voltages were fine so it was a case of replacing it. The input DC voltage was 477VDC which limits the numbers of choices available for a 2Kw replacement. [ 73 more words. ] http://inverterrepairsadelaide.com.au//another-eversolar-/

04.01.2022 If your Macsolar inverter has failed, you need to read this blog and understand what were explaining... http://inverterrepairsadelaide.com.au//growatt-replaces-m/

04.01.2022 http://inverterrepairsadelaide.com.au//toxic-landfill-use/

03.01.2022 SAVE UP TO 88% ON YOUR LIGHTING COSTS. Theres a far better alternative to halogen lamps and theyre L.E.Ds. Learn how to slash your light bill and gain extra light by reading this blog. http://inverterrepairsadelaide.com.au//danger-cost-haloge/

03.01.2022 In recent times, weve received calls from customers whos solar systems have stopped working. The reason is because the inverter has broken down but replacing the inverter isnt an option because it was installed with Sunpower panels. Click the link to learn more... http://inverterrepairsadelaide.com.au//sunpower-panel-fro/

03.01.2022 If your Fronius inverter is scrolling between "Startup" and "State 301" like this video demonstrates it means the DC-AC printed circuit board (PCB) has stopped working. We can replace this board for you and get your inverter back up and running however in all likelihood your inverter will be out of warranty and it MAY NOT be worth repairing. Below is a picture of an IG20 which had this issue and we replaced it with a Fronius Galvo 2.0-1. [ 257 more words. ] http://inverterrepairsadelaide.com.au//fronius-startup-st/

03.01.2022 This morning we replaced 2 x Kaco 1.5Kw inverters due to a "Failure DC Link" error. Because of the lack of support from Kaco in Australia, we decided to replace them both with Fronius Galvos. In the pictures below youll see one of the inverters demonstrating the printed circuit board failed components. On the top side of the board you can clearly see the burnt components and on the underneath of the board the damaged transformers (chokes) are visible by way of discolouring. [ 303 more words. ] http://inverterrepairsadelaide.com.au//kaco-inverter-fail/

02.01.2022 Ever wondered which roof is best to mount your solar panels on? This blog will clear it all up for you. http://inverterrepairsadelaide.com.au//solar-panel-mounti/

02.01.2022 How and when should you clean your solar panels? This is a question were asked all the time and the answers are on this blog. http://inverterrepairsadelaide.com.au//17/clean-solar-pan/

02.01.2022 If your Macsolar inverter has failed, you need to read this blog and understand what we're explaining... http://inverterrepairsadelaide.com.au//growatt-replaces-m/