20.01.2022 A burst 30uF capacitor measuring 0.34nF. A burntout 25A 3kA circuit breaker. kA rating too low and trip rating too high. Related with 6kA 20A.



19.01.2022 Never run a ducted air conditioner without a return air filter or even a very dirty one.

19.01.2022 Basin / vanity ready for installation.

18.01.2022 A burnt out hot water system element 3600W.



17.01.2022 Often having to go onto peoples roofs to gain access to the ceiling space, rather than going through the manhole, we often find cracked tiles and as part of our great service, we repair them for free.

16.01.2022 A poor brazing job. The result. Lost 1.7 kg R410A gas.

11.01.2022 Inside a Circuit Breaker. by Bigclivedotcom on YouTube. https://youtu.be/JbyTHlx4tQM



10.01.2022 Sound studio sub - board.

10.01.2022 Brand new flick mixer tap with a cracked brass nut.

08.01.2022 Diagram of heater unit.

07.01.2022 Short circuit found under the house due to rising damp plus shorts found in ceiling. The house still had steel conduit with cotton covered cables in them. Although it had been partly rewired with new cable. It was a messy job and not labelled. The previous electrician removed the RCD for a regular breaker on P1 and had also disabled the RCD section of the lights circuit by removing the N and connecting it directly to the N bus.

07.01.2022 Often having to go onto people's roofs to gain access to the ceiling space, rather than going through the manhole, we often find cracked tiles and as part of our great service, we repair them for free.



07.01.2022 Home heating using gas powered heater, heating water from a cistern pumped through a heat exchanger that has air pumped through it that is ducted throughout the house.

06.01.2022 One unhappy capacitor spills his guts.

03.01.2022 A cracked 5/8th flare nut. A very rare failure and hard to spot.

03.01.2022 This 500V 50uF capacitor has seen better days.

02.01.2022 An unorthodox placement of an isolation switch / circuit breaker. Any permanently wired appliance like an air conditioner is required by law to have a mains isolator mounted close to the device. This is done for safety reasons because if a serviceman simply turns off the circuit breaker at the main board then goes to service the unit over at the other side of the house. Someone else may inadvertently turn the breaker back on and not realise there is someone working on the uni...t. (A potentially lethal scenario). By disabling the power from an isolation switch mounted nearby, the serviceman can see if anyone approaches the switch.