25.01.2022 The homeowner or participant may choose to have these items included in the bathroom modifications, and separately fund the items with the builder. These items may include, but are not limited to: - Upgrade or replacement of the existing hot water system. - Plumbing works beyond the modified bathroom. - Replacement of taps, shower heads or plumbing fixtures that could otherwise be reused, in accordance with builder and/or plumber certification/compliance requirements (unless ...clinical evidence is provided to support the need for a different type of fitting). - Upgrade or replacement of other bathroom fittings and fixtures that could otherwise be reused. - Electrical upgrade or replacement of electrical wiring, main switchboard and circuits. - Additional electrical fixtures, such as general power outlets (unless required on the basis of being positioned to enable accessibility or relocated as a result of the modifications). - Folding glass shower screens. - Baths, unless there is specific clinical evidence to support the need. See more



23.01.2022 Hoist Transfer A suitable ceiling hoist structural support may be required for the roof space above the bedroom ceiling, where a participant is reliant on hoist transfers to and from their bed. The Assessor would consider the suitability of a mobile lifting hoist and also the participant’s carer supports where relevant. The ceiling hoist structural support would be determined in accordance with the hoist manufacturers or installer’s recommendations regarding the proposed hoist type, point loads, structural support method and specific location. The type of roof and wall construction of the participant’s dwelling would also impact on the determination of the most reasonable method of support.

23.01.2022 Book your Home Modification Consultation now! Click here: https://www.thetrendytradies.com.au/Calendar

21.01.2022 Shower Curtain Where a shower curtain is to be provided, it is typically on a suspended ‘L’ shaped curtain track with intermediate ceiling support. If the shower base is located in close proximity (within 300mm) to the bathroom door, it may be appropriate to provide an ‘ancillary support’ to the shower base. A small, fixed shower screen ‘nib’ (of at least 150mm wide) to preclude water splashing under the shower curtain, would protect the bathroom entrance from moisture (the shower curtain would slide along the inside of the nib).



21.01.2022 A robe of 1400mm width shall be provided within the bedroom, clear of the required bedroom size and with a minimum space of 1540mm in front of the robe. The 1400mm width robe can have multiple smaller sections within the one 1400mm space.

20.01.2022 Book your Home Modification Consultation

20.01.2022 What is included in a Kitchen Home Modification? These items may include, but are not limited to: Upgrade or replacement of the entire kitchen and/or appliances. Upgrade or replacement of the existing hot water system. Plumbing beyond the modified kitchen or appliance being altered.... Electrical upgrade or replacement of electrical wiring, main switchboard and circuits. Upgrade or replacement of kitchen fittings and fixtures that can otherwise be reused and are not being replaced with a different type due to clinical evidence (such as replacement of different types of kitchen taps and joinery handles that would support independent use). See more



18.01.2022 Toilets Modifications to an existing toilet which may meet the reasonable and necessary criteria for funded supports include: Replacement of the toilet seat. Addition of wall-mounted grab rails, drop-down grab rails or other assistive technology.... If a new toilet pan and cistern is required, the toilet suite would need to meet the reasonable and necessary criteria. Although an AS 1428.1 compliant toilet pan may be clinically justified as being effective and beneficial with regard to current good practice and representing value for money, there are typically many toilet suite models that would also be suitable for the participant. Key consideration should be given to the position and set-out of the toilet pan, which is often what makes the toilet functional, safe and accessible. Many typical toilet suite models can comply for use with a mobile shower commode. See more

17.01.2022 Light switches shall be positioned in a consistent location: Between 900mm 1000mm above the FFL, and Horizontally aligned with the door handle at the entrance to a room. For ease of access and consistency of locations.

15.01.2022 Hand Basins Where practical and appropriate, the existing hand basin and/or vanity would be retained. Modifications to a hand basin and/or vanity that may meet the reasonable and necessary criteria for funded supports include: Modifications to existing vanity joinery to facilitate knee/foot clearance for a wheelchair user. Replacement of an existing hand basin with a new semi-recessed type hand basin, to increase accessibility for a wheelchair user (which would also most like...ly require a new vanity top). Alteration of the height of a hand basin and/or vanity for a wheelchair or a standing user, based on clinical evidence. Replacement of existing taps with accessible taps, such as mixer taps with lever handles (and possibly extended lever handles). See more

13.01.2022 CALLING ALL OCCUPATIONAL THERAPISTS If you are an OT in the Greater Sydney area then click the link we’d like to connect with you. https://www.thetrendytradies.com.au/Consultation

11.01.2022 Before and After Here is a sneak peak at some of The Trendy Tradies work. Taken from one of our recent bathroom modifications. If you'd like more details on what we do please get in touch with us via the page. We look forward to hearing from you!



09.01.2022 Kitchen Modifications The following kitchen modifications that would typically meet the NDIS reasonable and necessary criteria, may include: - Removal of cupboard joinery under nominated areas of kitchen benches to provide for knee or foot clearance particularly for wheelchair users. Areas of under bench clearance considered reasonable for a wheelchair user may include kitchen sink, hotplate and bench area for meal preparation tasks. - Height adjustment of nominated sections ...of kitchen bench may involve new sections of joinery and alterations to existing splashback. - Changes to nominated appliances. - Joinery changes to facilitate an area of accessible storage. - Additional GPO(s) within an accessible reach range. - A mobile bench on castor wheels and manually height adjustable. See more

04.01.2022 Carpets if provided within the dwelling, shall be provided with pile height or thickness not more than 11mm and carpet backing not more than 4mm bringing the total height to a maximum of 15mm. To assist persons that require the use of a wheelchair for mobility. Note that attention should be provided to the density of the carpet and the quality of the underlay which may make floor unsuitable for wheelchairs regardless of the pile height of the carpet.

04.01.2022 Bedroom Modifications of a participant’s primary bedroom within their home may meet the reasonable and necessary criteria for a funded support. Typically, the primary bedroom will be the main bedroom on the same level as the entry door to the dwelling, which provides the greatest circulation space (particularly for a wheelchair user) and is located adjacent or as close as possible to the accessible bathroom used by the participant.

03.01.2022 Basins, sinks and tubs shall be provided with sensor type or lever-style tap. The tap shall be located such that the operable parts of the lever tap and water source is not more than 300mm from the edge of benchtop/ laundry tub trough/bench. For ease of operation for all users.

02.01.2022 Types of appropriate mechanisms for operation of kitchen cabinetry shall be one or more of the options as noted below: D pull cupboard handles located towards the top of below-bench cupboards; D pull cupboard handles located towards the bottom of overhead cupboards; Overhanging lip of minimum 20mm for overhead cupboards;... Push to release mechanisms for both overhead and below-bench cupboards. Design feature enables participant to operate in a seated or standing position with limited hand and finger movement and dexterity. Drawers under the benchtop are preferred to the cupboards. See more

01.01.2022 Electrical Changes to electrical wiring, fixtures and outlets would be based on clinical evidence for the participant’s requirements. The following electrical works may be required within the bedroom: An additional General Power Outlet (GPO) at ceiling level on or within the roof space for an overhead hoist. Additional GPO(s) on the bedhead wall for medical or disability related equipment (such as inflatable mattress, electric bed, respiratory equipment). Where the participant’s welfare is at risk, additional GPO(s) connected to an uninterrupted power system, and/or suitable air conditioning within the bedroom (such as a split system).